Description
Matched system provides advanced energy efficiency and comfort thru two stage cooling and heating. Precision temperature and quiet operation provided by variable speed blower motor. Certificate AHRI 209068071, Actual SEER2 – 16
Heat-Pump TRANE 4TWR6024N1000* – Trane XR16: This model balances cost and performance with a SEER2 rating around 16, offering dependable energy savings and enhanced comfort due to improved airflow management.
– Good energy efficiency with SEER2 rating of 16
– Cost-effective and reliable
– Enhanced airflow control for better comfort
Air Handler TRANE TEM6A0B30H21S* – Trane TEM6 Series: advanced technology that allows precise control of the air volume, improving the overall efficiency and comfort of your HVAC system. Its ability to manage humidity levels makes it ideal for climates prone to moisture.
– Highly efficient variable-speed operation with multiple stages for precise comfort control.
– Whisper-quiet operation, superior humidity control, built-in air filtration and purification options.
– Top-of-the-line comfort and efficiency for the most discerning homeowners.
– Unmatched performance and long-lasting durability backed by the Trane name.
Electric Heater TRANE BAYHTR1505BRK*
Heat Strip Electric heater 5 KW
Thermostat is not included. Can be used existing one if it meets to a new system requirements.
Warranty on equipment/works – according to manufacturer’s/contractor’s term and conditions.
Trane Extended Limited Warranty:
– 10 years on coil and functional parts
– 12 years on compressor
Warranty on installation works – 12 month
Extended Labor Warranty – 5 years (Maintenance agreement required)
All necessary materials that must be replaced to keep your new AC system running efficiently and safety and to pass a city inspection
Service works:
– City Permit
Professional installation works in accordance with mechanical city code:
– Remove and recycle existing equipment, cleanup site when finished
– Customer flooring protected with drop clothes
– Existing refrigerant recovered and recycled in accordance with the clean air act
– Installation of new system units
– Exterior section of refrigerant line insulation replaced with exterior-grade pipe insulation
– Copper refrigerant lines vacuumed and filter drier installed to prevent moisture damage
– Connecting to existing ductwork
– all necessary connection to existing communication lines (electricity, gas and flue pipe)
– Thermostat wiring connection
– Condensate line connection to existing drainage with proper P-trap and cleaning access
– All seams between equipment, platform and ductwork sealed airtight
– Adjust refrigerant charge and blower speed to provide optimal performance
Heat source: Electric
HP / AC: Heat-Pump
AHU type: Upflow/Horizontal
Tonnage: 1.5, 2
Brand: TRANE
Condenser unit stages: 2
Indoor unit type: Air Handler
SEER2: 16 SEER
Coil/El.Heater: BAYHTR1505BRK*
GF/AHU: TEM6A0B30H21S*
Condenser unit location: Ground
Flow direction location: Upflow
Carrier Performance 25TPB724
Carrier Infinity FT4BNXB36
Lennox DLSC SL25XPV-024
Lennox DLSC CBA38MV-030
Goodman GSZC702410
Goodman AMVT30CP1400