Description
Matched system provides advanced energy efficiency and comfort thru two stage cooling and heating. Precision temperature and quiet operation provided by variable speed blower motor. Certificate AHRI 209068112, Actual SEER2 – 15.6
Heat-Pump TRANE 4TWX7060E1000* – Trane XL17i: Features a high SEER2 rating for better energy savings and two-stage cooling to enhance indoor comfort. It is an excellent choice for those seeking efficiency and performance.
– SEER2 rating up to 17 for high energy savings
– Two-stage cooling for consistent comfort
– Reliable performance and longevity
Air Handler TRANE TEM6B0C60H51S* – Trane TEM6 Series: advanced technology that allows precise control of the air volume, improving the overall efficiency and comfort of your HVAC system. Its ability to manage humidity levels makes it ideal for climates prone to moisture.
– Highly efficient variable-speed operation with multiple stages for precise comfort control.
– Whisper-quiet operation, superior humidity control, built-in air filtration and purification options.
– Top-of-the-line comfort and efficiency for the most discerning homeowners.
– Unmatched performance and long-lasting durability backed by the Trane name.
Electric Heater TRANE BAYHTR1517BRK*
Heat Strip Electric heater 17 KW
Thermostat is not included. Can be used existing one if it meets to a new system requirements.
Warranty on equipment/works – according to manufacturer’s/contractor’s term and conditions.
Trane Extended Limited Warranty:
– 10 years on coil and functional parts
– 12 years on compressor
Warranty on installation works – 12 month
Extended Labor Warranty – 5 years (Maintenance agreement required)
All necessary materials that must be replaced to keep your new AC system running efficiently and safety and to pass a city inspection
Service works:
– City Permit
Professional installation works in accordance with mechanical city code:
– Remove and recycle existing equipment, cleanup site when finished
– Customer flooring protected with drop clothes
– Existing refrigerant recovered and recycled in accordance with the clean air act
– Installation of new system units
– Exterior section of refrigerant line insulation replaced with exterior-grade pipe insulation
– Copper refrigerant lines vacuumed and filter drier installed to prevent moisture damage
– Connecting to existing ductwork
– all necessary connection to existing communication lines (electricity, gas and flue pipe)
– Thermostat wiring connection
– Condensate line connection to existing drainage with proper P-trap and cleaning access
– All seams between equipment, platform and ductwork sealed airtight
– Adjust refrigerant charge and blower speed to provide optimal performance
Heat source: Electric
HP / AC: Heat-Pump
AHU type: Upflow/Horizontal
Tonnage: 5
Brand: TRANE
Condenser unit stages: 2
Indoor unit type: Air Handler
SEER2: 17 SEER
Coil/El.Heater: BAYHTR1517BRK*
GF/AHU: TEM6B0C60H51S*
Condenser unit location: Ground
Flow direction location: Upflow
Carrier Carrier Performance 25TPB760
Carrier Infinity FT4BNXB60
Lennox DLSC SL25XPV-060
Lennox DLSC CBA38MV-060
Goodman GSZC1806010
Goodman AMVT60CP1400