Description
Air Conditioner TRANE 4TTX6024J1000 – XL16i series, 16 SEER
-Durable Climatuff® compressor
-Full-side louvered panels
-WeatherGuard™ II top
-Baked-on powder paint
-Corrosion-resistant Weatherguard™ fasteners
-All-aluminum Spine Fin™ outdoor coil
-DuraTuff™ non-corrosive base pan
-Unique mounting of shaft down fan motor
-Variable-speed fan motor
-Quick-Sess cabinet with full coil protection
Gas Furnace TRANE S8X1B040M2PSA – S8X1 series Gas Furnace, 80% AFUE, Single Stage
– Nine tap blower motor
– Self-diagnostic microelectronic controller
– Heavy steel cabinet
– Durable silicon nitride hot surface igniter
– Multi-port, in-shot burners
– Tubular steel heat exchanger
– Pre-painted galvanized steel cabinet
– Insulated cabinet for quiet operation
Evaporator Coil TRANE 4TXCB004DS3HCA – 4TXC-DS Aluminum High Efficiency Stage System Coil
– All Aluminum Construction
– Leak Tested
– Cleaned Coils
– Factory Installed TXV
– Foil Backed Insulation
– Noncorrosive Drain Pan
– Painted Finish
Thermostat
Communicating thermostat is not required. Can be used existing one if it fits to a new system requirement.
Warranty on equipment/works – according to manufacturer’s/contractor’s term and conditions.
Trane Extended Limited Warranty:
– 10 years on coil and functional parts
– 20 years on heat exchanger
– 12 years on compressor
Warranty on installation works – 12 month
All necessary materials that must be replaced to keep your new AC system running efficiently and safety and to pass a city inspection
Service works:
– City Permit
Professional installation works in accordance with mechanical city code:
– Remove and recycle existing equipment, cleanup site when finished
– Customer flooring protected with drop clothes
– Existing refrigerant recovered and recycled in accordance with the clean air act
– Installation of new system units
– Exterior section of refrigerant line insulation replaced with exterior-grade pipe insulation
– Copper refrigerant lines vacuumed and filter drier installed to prevent moisture damage
– Connecting to existing ductwork
– all necessary connection to existing communication lines (electricity, gas and flue pipe)
– Thermostat wiring connection
– Condensate line connection to existing drainage with proper P-trap and cleaning access
– All seams between equipment, platform and ductwork sealed airtight
– Adjust refrigerant charge and blower speed to provide optimal performance
AHU type: Upflow/Horizontal
Condenser unit location: Ground
Flow direction location: Upflow
Heat source: Natural gas
HP / AC: Air Conditioner
Tonnage: 2