Description
The first 15-SEER Inverter condenser on the market. This system boasts a inverter drive which adjusts the speed of the compressor to optimize comfort, while keeping sound levels to a minimum and utilizing the right amount of energy to achieve maximum comfort. Certificate AHRI 208128246, Actual SEER2 – 16.1
Heat-Pump BOSCH BOVA-60HDN1-M15G – BOVA15 series Inverter Heat-Pump:
– Fully modulating inverter drive to precisely match the heating/cooling load
– The air coil design provides exceptional heat transfer and low air-resistance for high-efficiency operation that can help lower your energy costs
– The direct-drive fan blades provide vortex suppression to reduce sound of airflow exiting the condensing section
– The condensing units come standard with an electronic expansion valve (EEV) to ensure proper refrigerant flow during all conditions
Air Handler BOSCH BVA-48WN1-M20 – BVA20 series variable speed Air Hundler
– Two stage constant torque ECM style air handler
– All-Aluminum Coil – With excellent heat transfer, efficiency, and humidity removal
– Integrated Drain Pan – Made from corrosion-resistant composite material
– Painted galvanized steel cabinet is salt spray tested for improved durability and corrosion-resistance
Electric Heater BOSCH EHK-15B
Heat Strip Electric heater 15 KW
Thermostat is not included. Can be used existing one if it meets to a new system requirements.
Warranty on equipment/works – according to manufacturer’s/contractor’s term and conditions.
BOSCH Extended equipment Warranty:
– 10 years on coil and functional parts
– 10 years on compressor
Warranty on installation works – 12 month
Extended Labor Warranty – 5 years (Maintenance agreement required)
All necessary materials that must be replaced to keep your new AC system running efficiently and safety and to pass a city inspection
Service works:
– City Permit
Professional installation works in accordance with mechanical city code:
– Remove and recycle existing equipment, cleanup site when finished
– Customer flooring protected with drop clothes
– Existing refrigerant recovered and recycled in accordance with the clean air act
– Installation of new system units
– Exterior section of refrigerant line insulation replaced with exterior-grade pipe insulation
– Copper refrigerant lines vacuumed and filter drier installed to prevent moisture damage
– Connecting to existing ductwork
– all necessary connection to existing communication lines (electricity, gas and flue pipe)
– Thermostat wiring connection
– Condensate line connection to existing drainage with proper P-trap and cleaning access
– All seams between equipment, platform and ductwork sealed airtight
– Adjust refrigerant charge and blower speed to provide optimal performance
Heat source: Electric
HP / AC: Heat-Pump
AHU type: Upflow/Horizontal
Tonnage: 3.5, 4
Brand: BOSCH
Condenser unit stages: variable
Indoor unit type: Air Handler
SEER2: 16 SEER
Coil/El.Heater: EHK-15B
GF/AHU: BVA-48WN1-M20
Condenser unit location: Ground
Flow direction location: Upflow
Carrier Infinity 25VNA848
Carrier Infinity FT4BNXB48
Lennox DLSC SL25XPV-048
Lennox DLSC CBA38MV-048
Goodman GSZC704810
Goodman AMVT48CP1400